{"id":769,"date":"2026-08-21T19:03:56","date_gmt":"2026-08-21T17:03:56","guid":{"rendered":"https:\/\/www.mjm-automation.sk\/?p=769"},"modified":"2026-08-21T19:03:57","modified_gmt":"2026-08-21T17:03:57","slug":"za-hranicou-silnoprudu-integracia-tienenie-a-bms-monitorovacich-systemov-medicialnych-plynov","status":"publish","type":"post","link":"https:\/\/www.mjm-automation.sk\/en\/nezaradene\/za-hranicou-silnoprudu-integracia-tienenie-a-bms-monitorovacich-systemov-medicialnych-plynov\/","title":{"rendered":"Za hranicou silnopr\u00fadu: Integr\u00e1cia, tienenie a BMS monitorovac\u00edch syst\u00e9mov medici\u00e1lnych plynov"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Ke\u010f sa povie in\u0161tal\u00e1cia medici\u00e1lnych plynov, v\u00e4\u010d\u0161ina \u013eud\u00ed si predstav\u00ed zv\u00e1ranie meden\u00fdch trubiek a in\u0161tal\u00e1ciu reduk\u010dn\u00fdch ventilov. Ale my elektrik\u00e1ri vieme, \u017ee bez prec\u00edzne nak\u00e1blovan\u00e9ho, odru\u0161en\u00e9ho a integrovan\u00e9ho monitorovacieho syst\u00e9mu je ak\u00e1ko\u013evek kysl\u00edkov\u00e1 stanica len natlakovanou bombou naslepo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V <strong>MJM-AUTOMATION<\/strong> sp\u00e1jame \u0161pi\u010dkov\u00fdch elektrik\u00e1rov \u2013 \u017eivnostn\u00edkov s projektmi, ktor\u00e9 si vy\u017eaduj\u00fa viac ne\u017e len natiahnutie CYKYny do rozv\u00e1dza\u010da. Dnes sa pozrieme na to, s \u010d\u00edm sa re\u00e1lne stretne\u0161 pri o\u017eivovan\u00ed a \u00fadr\u017ebe signaliza\u010dn\u00fdch panelov a ich integr\u00e1cii do nadraden\u00fdch syst\u00e9mov nemocnice.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. Anal\u00f3g verzus Digit\u00e1l: Pr\u00fadov\u00e9 slu\u010dky 4-20 mA v zaru\u0161enom prostred\u00ed<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Mozgom celej plynovej infra\u0161trukt\u00fary s\u00fa lok\u00e1lne signaliza\u010dn\u00e9 panely (napr\u00edklad na JIS, ARE alebo opera\u010dn\u00fdch s\u00e1lach), ktor\u00e9 zbieraj\u00fa d\u00e1ta z tlakov\u00fdch sn\u00edma\u010dov. Tieto sn\u00edma\u010de naj\u010dastej\u0161ie komunikuj\u00fa cez <strong><a href=\"https:\/\/www.hengko.com\/sk\/news\/what-is-4-20ma-output\/\" data-type=\"link\" data-id=\"https:\/\/www.hengko.com\/sk\/news\/what-is-4-20ma-output\/\" target=\"_blank\" rel=\"noreferrer noopener\">pr\u00fadov\u00fa slu\u010dku 4-20 mA<\/a><\/strong>. Pre\u010do nie 0-10 V? Preto\u017ee nemocnica je extr\u00e9mne zaru\u0161en\u00e9 prostredie.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ako \u017eivnostn\u00edk na stavbe mus\u00ed\u0161 r\u00e1ta\u0165 s t\u00fdm, \u017ee tvoje trasy p\u00f4jdu \u010dasto v s\u00fabehu, alebo bl\u00edzko technol\u00f3gi\u00ed ako s\u00fa MRI (magnetick\u00e1 rezonancia), r\u00f6ntgeny \u010di v\u00fdkonn\u00e9 <a href=\"https:\/\/frekvencnemenice.sk\/?gad_source=1&amp;gad_campaignid=796169173&amp;gbraid=0AAAAADsAeQLZj-yd8maHHfqz43cZA2jfL&amp;gclid=CjwKCAjw7p_UBhBlEiwAhpIs7-4zUOFoDg45Nb9yhShg8FoiA0okWC7GmKkpGfDngp0JZC20qm_0-hoCGqIQAvD_BwE\" data-type=\"link\" data-id=\"https:\/\/frekvencnemenice.sk\/?gad_source=1&amp;gad_campaignid=796169173&amp;gbraid=0AAAAADsAeQLZj-yd8maHHfqz43cZA2jfL&amp;gclid=CjwKCAjw7p_UBhBlEiwAhpIs7-4zUOFoDg45Nb9yhShg8FoiA0okWC7GmKkpGfDngp0JZC20qm_0-hoCGqIQAvD_BwE\" target=\"_blank\" rel=\"noreferrer noopener\">frekven\u010dn\u00e9 meni\u010de VZT<\/a>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Praktick\u00e1 v\u00fdzva:<\/strong> Spr\u00e1vne uzemnenie tienenia (FTP\/STP k\u00e1blov alebo \u0161peci\u00e1lnych JY(St)Y k\u00e1blov). Tienenie mus\u00ed by\u0165 uzemnen\u00e9 striktne <strong>len na jednom konci<\/strong> (zvy\u010dajne v centr\u00e1lnom rozv\u00e1dza\u010di), aby si nevytvoril zemn\u00fa slu\u010dku (ground loop), ktor\u00e1 by do anal\u00f3gov\u00e9ho sign\u00e1lu zaniesla \u0161um. Pri poklese tlaku kysl\u00edka o 0,5 baru syst\u00e9m nesmie vyhl\u00e1si\u0165 falo\u0161n\u00fd poplach len preto, \u017ee o poschodie ni\u017e\u0161ie nabehol ve\u013ek\u00fd kompresor.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-1.jpg\" alt=\"\" class=\"wp-image-773\" srcset=\"https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-1.jpg 1000w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-1-300x300.jpg 300w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-1-150x150.jpg 150w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-1-768x768.jpg 768w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-1-12x12.jpg 12w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">2. Zbernicov\u00e9 syst\u00e9my a integr\u00e1cia do vel\u00edna (BMS)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Modern\u00e9 nemocnice u\u017e nefunguj\u00fa len na lok\u00e1lnych p\u00edpaj\u00facich krabi\u010dk\u00e1ch. V\u0161etky d\u00e1ta z reduk\u010dn\u00fdch stan\u00edc, odparova\u010dov a z\u00f3nov\u00fdch ventilov musia tiec\u0165 do centr\u00e1lneho vel\u00edna \u2013 do syst\u00e9mu BMS (<a href=\"https:\/\/en.wikipedia.org\/wiki\/Building_automation\" data-type=\"link\" data-id=\"https:\/\/en.wikipedia.org\/wiki\/Building_automation\" target=\"_blank\" rel=\"noreferrer noopener\">Building Management System<\/a>).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tu u\u017e tvoja pr\u00e1ca prech\u00e1dza do oblasti MaR a IT:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong><a href=\"https:\/\/papouch.com\/jak-zapojit-rs485-modbus-rtu-fv-elektrarna\/\" data-type=\"link\" data-id=\"https:\/\/papouch.com\/jak-zapojit-rs485-modbus-rtu-fv-elektrarna\/\" target=\"_blank\" rel=\"noreferrer noopener\">Modbus RTU (RS-485)<\/a> \/ BACnet:<\/strong> Mnoh\u00e9 hlavn\u00e9 centr\u00e1ly medici\u00e1lnych plynov vyu\u017e\u00edvaj\u00fa pre komunik\u00e1ciu s\u00e9riov\u00e9 linky. Tvojou \u00falohou pri mont\u00e1\u017ei je zabezpe\u010di\u0165 spr\u00e1vnu topol\u00f3giu zbernice (striktn\u00e1 &#8222;daisy chain&#8220; l\u00ednia bez odbo\u010diek) a nezabudn\u00fa\u0165 na <strong>termina\u010dn\u00e9 odpory (zvy\u010dajne 120 \u03a9)<\/strong> na koncoch linky. Odrazy sign\u00e1lu na zbernici pri vysok\u00fdch prenosov\u00fdch r\u00fdchlostiach dok\u00e1\u017eu znefunk\u010dni\u0165 komunik\u00e1ciu celej plynovej centr\u00e1ly.<\/li>\n\n\n\n<li><strong>Bezpotenci\u00e1lov\u00e9 kontakty vs. d\u00e1tov\u00e1 komunik\u00e1cia:<\/strong> Pri star\u0161\u00edch syst\u00e9moch, alebo pri po\u017eiadavk\u00e1ch na absol\u00fatnu &#8222;blbovzdornos\u0165&#8220;, sa st\u00e1le vyu\u017e\u00edvaj\u00fa rel\u00e9ov\u00e9 v\u00fdstupy (Common, NO, NC). Ako elektrik\u00e1r mus\u00ed\u0161 zabezpe\u010di\u0165, aby v pr\u00edpade \u00fapln\u00e9ho v\u00fdpadku nap\u00e1jania panela kontakt &#8222;odpadol&#8220; do alarmov\u00e9ho stavu (Fail-Safe zapojenie).<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-2.jpg\" alt=\"\" class=\"wp-image-772\" srcset=\"https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-2.jpg 1000w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-2-300x300.jpg 300w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-2-150x150.jpg 150w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-2-768x768.jpg 768w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-2-12x12.jpg 12w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">3. Kritick\u00e1 redundancia a nap\u00e1janie: Hra s izolovanou IT sie\u0165ou<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Medici\u00e1lne plyny spadaj\u00fa do kateg\u00f3rie \u017eivot zachra\u0148uj\u00facich syst\u00e9mov. Ich monitorovanie nikdy nevis\u00ed na jednom isti\u010di. Pri zap\u00e1jan\u00ed signaliza\u010dn\u00fdch panelov na s\u00e1lach sa stretne\u0161 s nemocni\u010dnou <strong>zdravotn\u00edckou IT sie\u0165ou (izolovanou s\u00fastavou)<\/strong>, ktor\u00e1 je nap\u00e1jan\u00e1 cez odde\u013eovacie <a href=\"https:\/\/www.ghvtrading.sk\/produkty\/elektricka-bezpecnost\/medics\/strazice-izolacie\" data-type=\"link\" data-id=\"https:\/\/www.ghvtrading.sk\/produkty\/elektricka-bezpecnost\/medics\/strazice-izolacie\" target=\"_blank\" rel=\"noreferrer noopener\">transform\u00e1tory so str\u00e1\u017ei\u010dom izola\u010dn\u00e9ho stavu (HIS)<\/a>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Dvojit\u00e9 nap\u00e1janie:<\/strong> Ka\u017ed\u00fd d\u00f4le\u017eit\u00fd panel medici\u00e1lnych plynov mus\u00ed by\u0165 nap\u00e1jan\u00fd z dvoch nez\u00e1visl\u00fdch zdrojov. Zvy\u010dajne ide o kombin\u00e1ciu siete z\u00e1lohovanej centr\u00e1lnou UPS a motorgener\u00e1torom.<\/li>\n\n\n\n<li><strong>\u00dadr\u017eba v ostrej prev\u00e1dzke:<\/strong> Ke\u010f ako \u017eivnostn\u00edk rob\u00ed\u0161 \u00fadr\u017ebu na t\u00fdchto rozv\u00e1dza\u010doch, mus\u00ed\u0161 presne vedie\u0165, ako syst\u00e9m prep\u00edna medzi zdrojmi. Neodborn\u00fd z\u00e1sah alebo skrat pri do\u0165ahovan\u00ed svoriek v paneli nevyhod\u00ed len tvoj isti\u010d, ale m\u00f4\u017ee aktivova\u0165 alarm izola\u010dn\u00e9ho stavu na celej opera\u010dnej s\u00e1le po\u010das prebiehaj\u00facej oper\u00e1cie.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-3.jpg\" alt=\"\" class=\"wp-image-771\" srcset=\"https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-3.jpg 1000w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-3-300x300.jpg 300w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-3-150x150.jpg 150w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-3-768x768.jpg 768w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-3-12x12.jpg 12w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">4. Sk\u00fa\u0161ky a kalibr\u00e1cia bez paniky<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Najv\u00e4\u010d\u0161ia sk\u00fa\u0161ka tvojej profesionality prich\u00e1dza pri odovzd\u00e1van\u00ed diela. Simul\u00e1cia kritick\u00fdch stavov (vysok\u00fd tlak, n\u00edzky tlak, v\u00fdpadok zdroja) znamen\u00e1, \u017ee v\u0161etky prepojenia musia zafungova\u0165. Sk\u00fasen\u00fd \u017eivnostn\u00edk vie, \u017ee predt\u00fdm, ne\u017e na sn\u00edma\u010di umele zhod\u00ed tlak, mus\u00ed cez r\u00e1diostanicu alebo telef\u00f3n komunikova\u0165 s dispe\u010dingom nemocnice. Syst\u00e9my medici\u00e1lnych plynov s\u00fa navrhnut\u00e9 tak, aby pri alarme &#8222;kri\u010dali&#8220; \u010do najhlasnej\u0161ie (opticky aj akusticky). Prepojenie a otestovanie sp\u00e4tnej v\u00e4zby (napr\u00edklad tla\u010didla &#8222;MUTE&#8220; na paneli) vy\u017eaduje perfektn\u00fa znalos\u0165 \u010d\u00edtania elektrotechnick\u00fdch sch\u00e9m dodan\u00fdch v\u00fdrobcom technol\u00f3gie.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-4.jpg\" alt=\"\" class=\"wp-image-770\" srcset=\"https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-4.jpg 1000w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-4-300x300.jpg 300w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-4-150x150.jpg 150w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-4-768x768.jpg 768w, https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-4-12x12.jpg 12w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Z\u00e1ver: Si pripraven\u00fd na t\u00fato ligu?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pr\u00e1ca na elektroin\u0161tal\u00e1ci\u00e1ch pre medici\u00e1lne plyny nie je o dr\u00e1\u017ekovan\u00ed stien. Je to hodin\u00e1rska pr\u00e1ca s k\u00e1blami, \u010d\u00edtanie zlo\u017eit\u00fdch MaR sch\u00e9m a obrovsk\u00e1 zodpovednos\u0165. Pre elektrik\u00e1rov \u2013 \u017eivnostn\u00edkov, ktor\u00ed maj\u00fa hlavu na spr\u00e1vnom mieste a vedia si poradi\u0165 so zbernicami a redundanciou, je to v\u0161ak jedna z najlep\u0161ie platen\u00fdch a najstabilnej\u0161\u00edch pr\u00e1c na trhu.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">V <strong>MJM-AUTOMATION<\/strong> vieme, \u010do t\u00e1to pr\u00e1ca obn\u00e1\u0161a. Ak si \u017eivnostn\u00edk, ktor\u00fd h\u013ead\u00e1 projekty, kde sa cen\u00ed odbornos\u0165, prec\u00edznos\u0165 a technick\u00e9 myslenie, pozri si na\u0161e aktu\u00e1lne ponuky projektov. Zabezpe\u010d\u00edme ti z\u00e1kazky, pri ktor\u00fdch tvoja odbornos\u0165 skuto\u010dne vynikne.<\/p>","protected":false},"excerpt":{"rendered":"<p>Ke\u010f sa povie in\u0161tal\u00e1cia medici\u00e1lnych plynov, v\u00e4\u010d\u0161ina \u013eud\u00ed si predstav\u00ed zv\u00e1ranie meden\u00fdch trubiek a in\u0161tal\u00e1ciu reduk\u010dn\u00fdch ventilov. Ale my elektrik\u00e1ri vieme, \u017ee bez prec\u00edzne nak\u00e1blovan\u00e9ho, odru\u0161en\u00e9ho a integrovan\u00e9ho monitorovacieho syst\u00e9mu je ak\u00e1ko\u013evek kysl\u00edkov\u00e1 stanica len natlakovanou bombou naslepo. V MJM-AUTOMATION sp\u00e1jame \u0161pi\u010dkov\u00fdch elektrik\u00e1rov \u2013 \u017eivnostn\u00edkov s projektmi, ktor\u00e9 si vy\u017eaduj\u00fa viac ne\u017e len natiahnutie CYKYny [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":774,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[25,33,26],"class_list":["post-769","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nezaradene","tag-elektrikari","tag-farmaceuticky-priemysel","tag-mjm-automation"],"rttpg_featured_image_url":{"full":["https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026.jpg",2048,1024,false],"landscape":["https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026.jpg",2048,1024,false],"portraits":["https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026.jpg",2048,1024,false],"thumbnail":["https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-150x150.jpg",150,150,true],"medium":["https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-300x150.jpg",300,150,true],"large":["https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-1024x512.jpg",1024,512,true],"1536x1536":["https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-1536x768.jpg",1536,768,true],"2048x2048":["https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026.jpg",2048,1024,false],"trp-custom-language-flag":["https:\/\/www.mjm-automation.sk\/wp-content\/uploads\/2026\/08\/mjm-automation-medicialne-plyny-21-08-2026-18x9.jpg",18,9,true]},"rttpg_author":{"display_name":"Milan Lys\u00edk","author_link":"https:\/\/www.mjm-automation.sk\/en\/author\/mjm-automation\/"},"rttpg_comment":0,"rttpg_category":"<a href=\"https:\/\/www.mjm-automation.sk\/en\/category\/nezaradene\/\" rel=\"category tag\">Nezaraden\u00e9<\/a>","rttpg_excerpt":"Ke\u010f sa povie in\u0161tal\u00e1cia medici\u00e1lnych plynov, v\u00e4\u010d\u0161ina \u013eud\u00ed si predstav\u00ed zv\u00e1ranie meden\u00fdch trubiek a in\u0161tal\u00e1ciu reduk\u010dn\u00fdch ventilov. Ale my elektrik\u00e1ri vieme, \u017ee bez prec\u00edzne nak\u00e1blovan\u00e9ho, odru\u0161en\u00e9ho a integrovan\u00e9ho monitorovacieho syst\u00e9mu je ak\u00e1ko\u013evek kysl\u00edkov\u00e1 stanica len natlakovanou bombou naslepo. V MJM-AUTOMATION sp\u00e1jame \u0161pi\u010dkov\u00fdch elektrik\u00e1rov \u2013 \u017eivnostn\u00edkov s projektmi, ktor\u00e9 si vy\u017eaduj\u00fa viac ne\u017e len natiahnutie CYKYny&hellip;","_links":{"self":[{"href":"https:\/\/www.mjm-automation.sk\/en\/wp-json\/wp\/v2\/posts\/769","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mjm-automation.sk\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mjm-automation.sk\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mjm-automation.sk\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mjm-automation.sk\/en\/wp-json\/wp\/v2\/comments?post=769"}],"version-history":[{"count":1,"href":"https:\/\/www.mjm-automation.sk\/en\/wp-json\/wp\/v2\/posts\/769\/revisions"}],"predecessor-version":[{"id":775,"href":"https:\/\/www.mjm-automation.sk\/en\/wp-json\/wp\/v2\/posts\/769\/revisions\/775"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mjm-automation.sk\/en\/wp-json\/wp\/v2\/media\/774"}],"wp:attachment":[{"href":"https:\/\/www.mjm-automation.sk\/en\/wp-json\/wp\/v2\/media?parent=769"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mjm-automation.sk\/en\/wp-json\/wp\/v2\/categories?post=769"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mjm-automation.sk\/en\/wp-json\/wp\/v2\/tags?post=769"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}